When you're dealing with complex manufacturing equipment and specialized products, reliable technical support makes all the difference. R. C. Davis provides knowledgeable assistance for our full range of industrial products across the United States, helping you troubleshoot issues, select the right solutions, and keep your operations running smoothly. Our US-based technical team understands the challenges you face and delivers practical guidance tailored to your specific needs. Reach out to us for prompt, professional technical assistance, or select a product below for technical information about our products.

Gloved hand smoothing wet concrete with a trowel on a freshly patched floor
True-Bond adhesive ad on blue background, showing a cracked surface and text about fixing holes, pits, and cracks

True-Bond™

General Directions:

Clean surface of loose aggregates, dirt, grease and oil, and dust. For best results, etch surface with 10-15% muriatic acid, flush with clean water and allow to dry. Pour all of container "B" into container "A" and mix thoroughly. Add 3-5 parts of dry sand and mix in thoroughly. Brush or trowel on as thick as needed to repair area. Pot life approximately 20 minutes. Because of its high early strength, True-Bond may be opened to traffic in six hours.


Small Quantity Mixing Directions:

  • 2 cups of part "A"
  • 1 cup of part "B"
  • Stir thoroughly for 1 minute
  • Add 9 cups of dry sand (you may use more or less sand to customize the mix for your application!)
  • Mix thoroughly again


Coverage: Approximately 200 sq. ft. at approximately ¼" thickness.


CAUTION!

True-Bond contains an alkaline amine. Avoid contact with skin or eyes. In case of contact, wash skin with soap and water. Flush eyes immediately with water and see doctor. If True-Bond is used indoors, provide adequate ventilation.

Pink True-Bond PS product label for a permanent concrete patch for holes, pits and cracks

True-Bond PS™

Bonds and cures on damp surfaces. A must for oily conditions!


General Directions:

Clean surface of loose aggregates, dirt, grease and oil, and dust. For best results, etch surface with 10-15% muriatic acid and flush with clean water. Pour all of container "B" into container "A" and mix thoroughly. Add 3-5 parts of dry sand and mix in thoroughly. Brush or trowel on as thick as needed to repair area. Pot life approximately 20 minutes. Because of its high early strength, True-Bond PS may be opened to traffic in six hours.


Small Quantity Mixing Directions:

  • 2 cups of part "A"
  • 1 cup of part "B"
  • Stir thoroughly for 1 minute
  • Add 9 cups of dry sand (use more or less sand to customize)
  • Mix thoroughly again


Coverage: Approximately 200 sq. ft. at approximately ¼" thickness.


CAUTION!

True-Bond PS Contains an alkaline amine. Avoid contact with skin or eyes. In case of contact, wash skin with soap and water. Flush eyes immediately with water and see doctor. If True-Bond PS is used indoors, provide adequate ventilation.

Yellow True-Bond Kote concrete sealer ad with black text and a large product can graphic

True-Bond KOTE™

General Directions:

Clean surface of loose aggregates, dirt, grease and oil, and dust. For best results, etch surface with 10-15% muriatic acid and flush with clean water. Allow surface to dry. Pour all of container "B" into Container "A". Hand mix thoroughly. Apply with short nap roller, brush or squeegee in a thin, even coat. Pot life approximately 20 minutes. Because of its high early strength, True-Bond KOTE may be open to traffic in six hours.


Slip Proof Application:

For non-slip finish, broadcast dry sand, aluminum oxide, or carborundum immediately after application (while True-Bond KOTE is still wet). When material is dry, sweep off excess aggregate and apply optional second coat (with or without aggregate).


Small Quantity Mixing Directions:

  • 2 cups of part "A"
  • 1 cup of part "B"
  • Stir thoroughly


Coverage: Approximately 300 sq. ft. per kit.


CAUTION!

True-Bond KOTE contains an alkaline amine. Avoid contact with skin or eyes. In case of contact, wash skin with soap and water. Flush eyes immediately with water and see doctor. If True-Bond KOTE is used indoors, provide adequate ventilation.

Yellow True Bond L.L.T. adhesive label with black text and product directions.

True-Bond LLT™

General Directions:

Clean surface of loose aggregates, dirt, grease and oil, and dust. For best results, etch surface with 10-15% muriatic acid and flush with clean water and allow to dry. Pour all of container "B" into container "A" and mix thoroughly. Add 3-5 parts of dry sand and mix in thoroughly. Brush or trowel on as thick as needed to repair area. Pot life approximately 20 minutes. Because of its high early strength, True-Bond LLT may be opened to traffic in six hours.


Small Quantity Mixing Directions:

  • 2 cups of part "A"
  • 1 cup of part "B"
  • Stir thoroughly for 1 minute
  • Add 9 cups of dry sand (use more or less sand to customize)
  • Mix thoroughly again


Coverage: Approximately 200 sq. ft. at approximately ¼" thickness.


CAUTION!

True-Bond LLT contains an alkaline amine. Avoid contact with skin or eyes. In case of contact, wash skin with soap and water. Flush eyes immediately with water and see doctor. If True-Bond LLT is used indoors, provide adequate ventilation.

Green True Bond CR chemical-resistant protective coating label with product image and instructions

True-Bond CR™

General Directions:

Clean surface of loose aggregates, dirt, grease and oil, and dust. For best results, etch surface with 10-15% muriatic acid, flush with clean water and allow to dry. Pour all of container "B" into container "A" and mix thoroughly. Add 3-5 parts of dry sand and mix in thoroughly. Brush or trowel on as thick as needed to repair area. Pot life approximately 20 minutes. Because of its high early strength, True-Bond CR may be opened to traffic in six hours.


Small Quantity Mixing Directions:

  • 2 cups of part "A"
  • 1 cup of part "B"
  • Stir thoroughly for 1 minute
  • Add 9 cups of dry sand (use more or less sand to customize)
  • Mix thoroughly again


Coverage: Approximately 200 sq. ft. at approximately ¼" thickness.


CAUTION!

True-Bond CR contains an alkaline amine. Avoid contact with skin or eyes. In case of contact, wash skin with soap and water. Flush eyes immediately with water and see doctor. If True-Bond CR is used indoors, provide adequate ventilation.

Yellow True-Bond CT adhesive package for holes, pits and cracks with black logo and text

True-Bond CT™

General Directions:

Clean surface of loose aggregates, dirt, grease and oil, and dust. For best results, etch surface with 10 - 15% muriatic acid and flush with clean water and allow to dry. Combine all of container "A" with container "B" and mix thoroughly. Add 3 to 5 parts of dry sand and mix in thoroughly. Brush or trowel on as thick as needed to repair area. Pot life approximately 20 minutes. Because of its high early strength, True-Bond CT may be open to traffic in six hours.


Small Quantity Mixing Directions:

  • 1 cup of part "A"
  • 1 cup of part "B"
  • Stir thoroughly for 1 minute
  • Add 6 cups of dry sand (use more or less sand to customize)
  • Mix thoroughly again


Coverage: Approximately 200 sq. ft. at approximately ¼" thickness.


CAUTION!

True-Bond CT contains an alkaline amine. Avoid contact with skin or eyes. In case of contact, wash skin with soap and water. Flush eyes immediately with water and see doctor. If True-Bond CT is used indoors, provide adequate ventilation.

Yellow True-Bond Gel adhesive label for concrete patching, with large black product name and damaged-surface graphic

True-Bond Gel™

General Directions:

Clean surface of loose aggregates, dirt, grease and oil, and dust. For best results, etch surface with 10 - 15% muriatic acid, flush with clean water and allow to dry. Combine all of container "A" with container "B" and mix thoroughly. Add 1 to 5 parts of dry sand and mix in thoroughly. Trowel on as thick as needed to repair area. Pot life approximately 20 minutes. Because of its high early strength, True-Bond Gel may be open to traffic in six hours.


Small Quantity Mixing Directions:

  • 1 cup of part "A"
  • 1 cup of part "B"
  • Stir thoroughly for 1 minute
  • Add 2 cups of dry sand (use more or less sand to customize)
  • Mix thoroughly again


Coverage: Approximately 200 sq. ft. at approximately ¼" thickness.


CAUTION!

True-Bond Gel contains an alkaline amine. Avoid contact with skin or eyes. In case of contact, wash skin with soap and water. Flush eyes immediately with water and see doctor. If True-Bond Gel is used indoors, provide adequate ventilation.

Orange vintage ad for Sure-Foot non-skid safety surface, showing a shoe and rake with U.S.A. compliance label

Sure-Foot™

General Directions:

Clean floors by acid etching with 15% muriatic acid removing surface grease, acid, oil, etc. Remove components A, B and C from mixing pail. Blend part A and B for 3-5 minutes. Then add aggregate and mix well. Then spread a thin, uniform coating with a squeegee, trowel, brush or short nap roller. Level all puddles. Tack free in 1 hour at 70 degrees Fahrenheit, ready for full traffic in 6 hours.


Small Quantity Mixing Directions:

  • 2 containers of part "A"
  • 2 containers of part "B"
  • 4 lbs of part "C"
  • Aggregate


Coverage: Approximately 300 sq. ft.


CAUTION!